Platform

See and control every unit. From one screen.

ProSensia is a small device fitted inside an existing air conditioner, and a web panel for the people who run the building. It is built for places with many separate units and no building-management system.

What works today, and what does not yet

Every capability carries its real status.

We label each function as working today, in development, or on the roadmap. If a label changes, it is because the product changed.

Working today

Live monitoring

Current draw, on/off state and running hours for every connected unit, by room, block and building.

Working today

Central control

Switch one unit, a block or a whole building from the panel, with roles for staff, heads of department and facility managers.

Working today

Timetable automation

Upload the timetable. Units follow it, and the schedule is stored on the device so it holds when the network does not.

Working today

Auto-shutdown

A unit left running is switched off after a set period, three hours by default.

Working today

Alerts

Abnormal current, a unit that fails to start, a device that has gone offline, a unit running outside its schedule.

In development

Per-unit baselines

Learning each unit’s own normal behaviour, so that drift is flagged for inspection before it becomes a fault.

In development

Predictive maintenance

Estimating when a unit is likely to need service. This needs months of collected data per site, and we will say so until it is validated.

In development

Environmental insights

Electricity-related emissions estimated from measured energy and published grid factors.

In development

Voltage and temperature sensing

Running in test firmware. Not yet part of the standard device.

Roadmap

Refrigerant-side sensing

Pressure or charge measurement would need new sensors. It is on the roadmap, not in the product.

Roadmap

Other equipment

Electric geysers first, then further building equipment.

Hardware

A board inside the unit, not a remote on the wall.

The device is built around an ESP32 microcontroller with a current sensor and a switching stage. It sits inside the indoor unit, out of reach, so it cannot be unplugged or bypassed the way an infrared controller can.

Because it measures the current the unit actually draws, it knows whether the unit is really running, for how long, and whether its electrical behaviour has changed.

Schedules are stored on the device. If the network drops, the timetable still runs, and readings are sent when the connection returns.

MeasuredStatus
Current drawn by the unitWorking today
On/off state and running hoursWorking today
Supply voltageIn testing
TemperatureIn testing
Refrigerant pressure or chargeNot measured
The panel

Room, block, building.

Control at three levels

Switch a single room, a block, or the whole building. Useful at the end of the day, during holidays, and when load must come down quickly.

Timetables, uploaded

Upload the timetable as a spreadsheet. Units follow it room by room. When the timetable changes, upload the new one.

Roles

Teachers, heads of department, facility staff and administrators see and control what their role allows.

Maintenance intelligence

From alerts today to prediction, honestly staged.

Stage 1 · working today

Detect

Rules catch what is already wrong: abnormal current, a failed start, an offline device, a unit running outside its schedule.

Stage 2 · in development

Flag

Each unit is compared with its own history. Drift is flagged for a technician to inspect. The system points; a person decides.

Stage 3 · in development

Predict

With enough validated data per site, estimate when service will be needed. Estimates, never guarantees, and only once we can show they hold.

A current sensor cannot diagnose a specific component by itself. It can show that a unit’s behaviour has changed, which is the signal a maintenance team rarely has.

Limits

What ProSensia does not do.

  • It does not read the manufacturer’s internal data. It measures with its own sensors.
  • It does not measure refrigerant, and makes no leak-detection claim.
  • It does not replace a building-management system in buildings with central plant.
  • It does not fit every unit. Compatibility is confirmed by a site survey.
  • It has not yet published a measured saving. When the pilot data supports a figure, it will appear on the proof page.