Sources and methods

Every number, and where it comes from.

The small codes beside figures on this site lead here. Each entry gives the figure as published, its source, the year it refers to, and the main thing to keep in mind when reading it.

CodeStatisticValueWhere, whenSource and caveat
A03Heatwaves have caused more deaths than all other natural hazards combinedqualitative
n/a
Australia
1900-2011 study period
Coates et al. 2014 (via Natural Hazards Research Australia)
Historic study
C03Heat-related deaths per year (45% in Asia; 36% in Europe)about 489000
deaths per year
World
2000-2019
WHO fact sheet: Heat and health (citing Zhao et al. 2021)
Modelled estimate
C05Heat-related excess deaths in Europe in summer 202261672
deaths
Europe
2022
WHO fact sheet: Heat and health
Estimate
E01Lifecycle carbon intensity of electricity458.29
gCO2e/kWh
World
2025
Ember (2026) via Our World in Data
Lifecycle basis; generation-based not consumption-based; annual average
E02Lifecycle carbon intensity of electricity346.56
gCO2e/kWh
Pakistan
2025
Ember (2026) via Our World in Data
Grid only; excludes distributed solar self-consumption and diesel generators
E03Lifecycle carbon intensity of electricity116.91
gCO2e/kWh
Austria
2025
Ember (2026) via Our World in Data
Imports not reflected
E04Lifecycle carbon intensity of electricity209.90
gCO2e/kWh
European Union (27)
2025
Ember (2026) via Our World in Data
E05Lifecycle carbon intensity of electricity525.18
gCO2e/kWh
Australia
2025
Ember (2026) via Our World in Data
National average; states differ widely
E06Lifecycle carbon intensity of electricity691.95
gCO2e/kWh
Saudi Arabia
2024
Ember (2026) via Our World in Data
2024 is latest year in dataset
E07Lifecycle carbon intensity of electricity467.51
gCO2e/kWh
United Arab Emirates
2024
Ember (2026) via Our World in Data
2024 is latest year in dataset
E08Lifecycle carbon intensity of electricity563.23
gCO2e/kWh
Egypt
2025
Ember (2026) via Our World in Data
EU01Buildings: share of EU final energy consumption / energy-related GHG emissions / share of buildings that are energy-inefficient40 / 36 / 75
percent
European Union
recital text
Directive (EU) 2024/1275 recital 6
Recital figures; underlying data years not stated
EU02Share of EU buildings built before 200085
percent
European Union
undated
European Commission EPBD page
EU03Annual energy renovation rate of EU buildingsabout 1
percent per year
European Union
undated
European Commission EPBD page
EU05Non-residential buildings must have building automation and control systems where feasible: HVAC rated output over 290 kW / over 70 kWby 31 Dec 2024 / by 31 Dec 2029
deadline
European Union
2024-2029
Directive (EU) 2024/1275 Article 13(9)
'Where technically and economically feasible'; national transposition by 29 May 2026 varies. Whether a ProSensia system counts as BACS under the standard EN ISO 52120 is unproven
G01Share of global final energy consumption used by building operations30
percent
World
2022-2023
IEA Buildings topic page
Rises to 34% if construction materials are included; operations only here
G03Share of global electricity consumption used in buildingsabout 50
percent
World
recent
IEA special report on buildings efficiency (executive summary)
Rounded statement ('half')
G04Air conditioners and electric fans: share of electricity used in buildings / of all global electricityabout 20 / 10
percent
World
2016
IEA The Future of Cooling
2018 report using 2016 data; still the most cited baseline. IEA 2023-2025 commentaries repeat ~10%
G05Growth in energy demand for space cooling by 2050 without efficiency actionmore than 3x
multiple
World
2016-2050
IEA The Future of Cooling
Reference scenario projection; old baseline
G09Efficiency of the average new air conditioner sold relative to the best available modelsabout half
ratio
World
2025
IEA commentary: Staying cool without overheating the energy system
Statement about new sales
G10People living in regions with high temperatures / share owning an air conditioner3.5 billion / about 15
people / percent
World
2025
IEA commentary: Staying cool without overheating the energy system
Rounded
G11Annual growth of space-cooling energy demand in buildings to 2035almost 4
percent per year
World
2025-2035
IEA commentary: Staying cool without overheating the energy system
Projection under stated policies
M01Cost savings of a predictive maintenance programme over preventive maintenance alone8 to 12
percent
Not specified (industrial/federal facilities)
pre-2010 studies
US DOE FEMP O&M Best Practices Guide Release 3.0 (PNNL-19634) ch.5
'Past studies have estimated'; not HVAC-specific; old
M02Cost savings of preventive maintenance over reactive maintenance12 to 18
percent
Not specified
pre-2010 studies
US DOE FEMP O&M Best Practices Guide Release 3.0 ch.5
Estimate
M05Annual cost of unplanned downtime to the world's 500 largest companies1.4 trillion USD (11% of revenues)
USD
World (largest 500 companies)
2023-2024
Siemens: The True Cost of Downtime 2024
Vendor study; heavy industry; not about HVAC. Use only on the industrial-scale scene with attribution
ME01Electricity demand growth in MENA: 2000-2024 / projected to 2035tripled (+1000 TWh) / +50%
multiple / percent
Middle East and North Africa
2000-2035
IEA The Future of Electricity in the Middle East and North Africa
Stated policies projection
ME02Cooling share of peak electricity demand / of annual electricity demandnearly half / one quarter
share
Middle East and North Africa
2024
IEA The Future of Electricity in the Middle East and North Africa
Regional average
ME04Average AC efficiency in MENA relative to Japan; peak demand growth avoidable by 2035 through AC efficiencyless than half; 35 GW
ratio / GW
Middle East and North Africa
2024-2035
IEA The Future of Electricity in the Middle East and North Africa
Efficiency of equipment not of maintenance
P07Kigali Amendment: ratified by Pakistan / in force / HFC cut required22 Oct 2025 / 20 Jan 2026 / 85% by 2047 from 2024-2026 baseline
date / percent
Pakistan
2025-2047
International Institute of Refrigeration news
Secondary summary of treaty status
R03100-year GWP of common AC refrigerants: R-22 / R-410A / R-32 / R-2901810 / 2088 / 675 / about 3
kg CO2e per kg
n/a
IPCC AR4 values
California Air Resources Board GWP table; EU Regulation 2024/573 Annex I
R-22 and R-410A confirmed in CARB table (B). R-32 and R-290 values are the standard AR4 figures but were not opened this session: confirm before use. AR5/AR6 values differ
W01Energy used in commercial buildings that is wasted through inefficiencyabout 30 (often cited as 'up to 30 or more')
percent
United States
undated estimate
US EPA ENERGY STAR / US DOE Commercial Buildings Integration
Long-standing estimate not a measured national average; US only. Always attribute and say 'estimated'
W03Median whole-building energy savings from fault detection and diagnostics software9
percent
United States
study period 2010s
Lawrence Berkeley National Laboratory
Buildings with central systems and BMS; not split units; median so half saw less

Company figures

Figures about ProSensia itself (four devices tested for more than a year, thirty in stock, milestones) come from company documents and the university’s certificate of implementation. They are marked “company records” where they appear.

Photographs

Building facade with outdoor air-conditioning units, Kuala Lumpur: Tinou Bao, “Kuala Lumpur air conditioning”, licensed under CC BY 2.0. Resized; markers are drawn over it on the page. The 87 marked units were counted by hand from the photograph. A real building, shown as an example; it is not a ProSensia site.

Other photographs are from Pexels and used under the Pexels License. They show example buildings, rooms and people; none of them is a ProSensia site or customer. One photograph (a control room) has had an employer logo removed.

Illustrations

The room, the air conditioner, the buildings and the daily schedules on the homepage are illustrations of how things work. They are generic, they are labelled, and they are not data from any site.

The film

The one-minute film uses the photographs credited above, path-traced concept renders of the device and of an air-conditioner interior (made for ProSensia in Blender), screenshots of the dashboard demo on simulated data, and a globe drawn from land dots with no borders. The music is original: it was synthesised for this film and samples no third-party recording. It has no voice-over.